SoftScopeのショートカットキー

ここで示すショートカットキーは、SoftScope 2.5.0のものです。

File

Name Sub Menu Operation Hot-key
Load State   Load saved state of SoftScope F2
Save State   Save state of SoftScope F3
Save As DAT   Save as DAT File format Ctrl + S
Save As JPG   Save as JPG File format  
Save As BMP   Save as BMP File format  
Save As Word   Saves waveform as word file F4
Save As Excel   Saves waveform as excel file F5
Option   Selects the waveform or screen option F6
Copy   Saves waveform to clipboard Ctrl + C
Load Reference   Load Reference file.  
Save Channel1 As Reference   Save and load channel 1 waveform as Reference waveform  
Save Channel2 As Reference   Save and load channel 2 waveform as Reference waveform  
Preview   Previews the waveform F7
Print   Prints the waveform Ctrl + P
Exit   Stops the SoftScope and return Ctrl + X

View

Name Sub Menu Operation Hot-key
File Toolbar   Shows/Hides File Toolbar Ctrl + F1
Display Toolbar   Shows/Hides Display Toolbar Ctrl + F2
Channel Toolbar   Shows/Hides Channel Toolbar Ctrl + F3
Run/Stop Toolbar   Shows/Hides Run/Stop Toolbar Ctrl + F4
Trigger Toolbar   Shows/Hides Trigger Toolbar Ctrl + F5
Util Toolbar   Shows/Hides Util Toolbar Ctrl + F6
Full Screen   Display Full Screen Alt + Enter

Display

Name Sub Menu Operation Hot-key
Line Join On/Off   Joins the waveform with line Ctrl + J
Persistence   Changes the persistence effect Ctrl + E
Intensity + Increases intensity of waveform Ctrl + Inc
- Decreases intensity of waveform Ctrl + Del
Label Edit On/Off   Inserts text to waveform Ctrl + L
Cross Cursor On/Off   On/Off Cross Cursor Ctrl + U
Horizontal Cursor On/Off   On/Off Horizontal Cursor  
Vertical Cursor On/Off   On/Off Vertical Cursor  

Channel

Name Sub Menu Operation Hot-key
Channel1 On/Off On/Off Shift + F1
Voltage Change Volt/Div setting Shift + F5
Probe Attenuation Change Probe Attenuation  
AC/DC/GND Coupling Change AC/DC/GND Shift + F2
Invert On/Off Change phase of waveform  
Bandwidth Limit Bandwidth limit  
Channel2 On/Off On/Off Shift + F7
Voltage Change Volt/Div setting Shift + F11
Probe Attenuation Change Probe Attenuation  
AC/DC/GND Coupling Change AC/DC/GND Shift + F8
Invert On/Off Change phase of waveform  
Bandwidth Limit Bandwidth limit  
Math On/Off On/Off Ctrl + M
Voltage Change Volt/Div setting  
Probe Attenuation Change Probe Attenuation  
Math Option Set Option of Math  
Reference On/Off On/Off  
Voltage Change Volt/Div setting  
Probe Attenuation Change Probe Attenuation  

Horizontal

Name Sub Menu Operation Hot-key
Time/Div   Change Time/Div setting Ctrl + T
Delay On/Off   On/Off Delay Ctrl + D

Trigger

Name Sub Menu Operation Hot-key
Trigger Source CH1   Selects CH1 from trigger source Shift + Ctrl + F1
Trigger Source CH2   Selects CH2 from trigger source Shift + Ctrl + F2
Slope   Selects Up/Down from Trigger Up/Down Shift + Ctrl + F3
Auto/Normal   Selects Normal/Auto from Trigger Normal/Auto Shift + Ctrl + F4
Advanced Trigger   Selects Advanced trigger Shift + Ctrl + F5
Trigger High Frequency Reject On/Off   Eliminate trigger high-frequency  

Acquire

Name Sub Menu Operation Hot-key
Run/Stop   Starts/Stops acquiring waveform Ctrl + R
Single Shot   Begins Single Shot operation Ctrl + H
Auto Set   Changes horizontal/vertical scale for waveform Ctrl + A
ETS On/Off   On/Off ETS  
Average   Changes average count number  
Peak Detection   Peak Detection On/Off  

Util

Name Sub Menu Operation Hot-key
FFT   Shows FFT form Ctrl + F
Measurement Time -  
Voltage -  
Upper/Lower Level Upper/Lower  
XY plot On/Off   On/Off XY plot Ctrl + Y
Calibration   Processes Offset calibration Shift + Ctrl + F6
ETS Calibration   Processes ETS calibration  

Measure

Name Sub Menu Operation Hot-key
Voltage Peak to Peak Measurement of Peak to Peak Voltage Ctrl + Alt + P
Maximum Measurement of Maximum Voltage Ctrl + Alt + X
Minimum Measurement of Minimum Voltage Ctrl + Alt + N
Amplitude Measurement of Amplitude Voltage Ctrl + Alt + A
Top Measurement of Top Voltage Ctrl + Alt + T
Base Measurement of Base Voltage Ctrl + Alt + B
Upper Measurement of Upper Voltage Ctrl + Alt + U
Middle Measurement of Middle Voltage Ctrl + Alt + M
Lower Measurement of Lower Voltage Ctrl + Alt + L
Mean Measurement of Mean Voltage Ctrl + Alt + E
Cycle Mean Measurement of Cycle Mean Voltage Ctrl + Alt + C
RMS Measurement of RMS Voltage Ctrl + Alt + R
Cycle RMS Measurement of Cycle RMS Voltage Ctrl + Alt + Y
Positive Overshoot Measurement of Positive Overshoot Voltage Ctrl + Alt + S
Negative Overshoot Measurement of Negative Overshoot Voltage Ctrl + Alt + G
Time Period Measurement of Period Ctrl + Alt + I
Frequency Measurement of Frequency Ctrl + Alt + F
Rise Time Measurement of Rise Time Ctrl + Alt + V
Fall Time Measurement of Fall Time Ctrl + Alt + Z
Positive Duty Cycle Measurement of Positive Duty Cycle Ctrl + Alt + J
Negative Duty Cycle Measurement of Negative Duty Cycle Ctrl + Alt + D
Positive Pulse Width Measurement of Positive Pulse Width Ctrl + Alt + W
Negative Pulse Width Measurement of Negative Pulse Width Ctrl + Alt + H
Upper/Lower Level   Set Upper/Lower ratio  

Help

Name Sub Menu Operation Hot-key
Help   Shows help file F1
About   Displays about Dialog Box F9

参考

  • Menu - SoftScope Help (/help.chm)