SoftScopeのショートカットキー
ここで示すショートカットキーは、SoftScope 2.5.0のものです。
File
Name |
Sub Menu |
Operation |
Hot-key |
Load State |
|
Load saved state of SoftScope |
F2 |
Save State |
|
Save state of SoftScope |
F3 |
Save As DAT |
|
Save as DAT File format |
Ctrl + S |
Save As JPG |
|
Save as JPG File format |
|
Save As BMP |
|
Save as BMP File format |
|
Save As Word |
|
Saves waveform as word file |
F4 |
Save As Excel |
|
Saves waveform as excel file |
F5 |
Option |
|
Selects the waveform or screen option |
F6 |
Copy |
|
Saves waveform to clipboard |
Ctrl + C |
Load Reference |
|
Load Reference file. |
|
Save Channel1 As Reference |
|
Save and load channel 1 waveform as Reference waveform |
|
Save Channel2 As Reference |
|
Save and load channel 2 waveform as Reference waveform |
|
Preview |
|
Previews the waveform |
F7 |
Print |
|
Prints the waveform |
Ctrl + P |
Exit |
|
Stops the SoftScope and return |
Ctrl + X |
View
Name |
Sub Menu |
Operation |
Hot-key |
File Toolbar |
|
Shows/Hides File Toolbar |
Ctrl + F1 |
Display Toolbar |
|
Shows/Hides Display Toolbar |
Ctrl + F2 |
Channel Toolbar |
|
Shows/Hides Channel Toolbar |
Ctrl + F3 |
Run/Stop Toolbar |
|
Shows/Hides Run/Stop Toolbar |
Ctrl + F4 |
Trigger Toolbar |
|
Shows/Hides Trigger Toolbar |
Ctrl + F5 |
Util Toolbar |
|
Shows/Hides Util Toolbar |
Ctrl + F6 |
Full Screen |
|
Display Full Screen |
Alt + Enter |
Display
Name |
Sub Menu |
Operation |
Hot-key |
Line Join On/Off |
|
Joins the waveform with line |
Ctrl + J |
Persistence |
|
Changes the persistence effect |
Ctrl + E |
Intensity |
+ |
Increases intensity of waveform |
Ctrl + Inc |
- |
Decreases intensity of waveform |
Ctrl + Del |
Label Edit On/Off |
|
Inserts text to waveform |
Ctrl + L |
Cross Cursor On/Off |
|
On/Off Cross Cursor |
Ctrl + U |
Horizontal Cursor On/Off |
|
On/Off Horizontal Cursor |
|
Vertical Cursor On/Off |
|
On/Off Vertical Cursor |
|
Channel
Name |
Sub Menu |
Operation |
Hot-key |
Channel1 |
On/Off |
On/Off |
Shift + F1 |
Voltage |
Change Volt/Div setting |
Shift + F5 |
Probe Attenuation |
Change Probe Attenuation |
|
AC/DC/GND Coupling |
Change AC/DC/GND |
Shift + F2 |
Invert On/Off |
Change phase of waveform |
|
Bandwidth Limit |
Bandwidth limit |
|
Channel2 |
On/Off |
On/Off |
Shift + F7 |
Voltage |
Change Volt/Div setting |
Shift + F11 |
Probe Attenuation |
Change Probe Attenuation |
|
AC/DC/GND Coupling |
Change AC/DC/GND |
Shift + F8 |
Invert On/Off |
Change phase of waveform |
|
Bandwidth Limit |
Bandwidth limit |
|
Math |
On/Off |
On/Off |
Ctrl + M |
Voltage |
Change Volt/Div setting |
|
Probe Attenuation |
Change Probe Attenuation |
|
Math Option |
Set Option of Math |
|
Reference |
On/Off |
On/Off |
|
Voltage |
Change Volt/Div setting |
|
Probe Attenuation |
Change Probe Attenuation |
|
Horizontal
Name |
Sub Menu |
Operation |
Hot-key |
Time/Div |
|
Change Time/Div setting |
Ctrl + T |
Delay On/Off |
|
On/Off Delay |
Ctrl + D |
Trigger
Name |
Sub Menu |
Operation |
Hot-key |
Trigger Source CH1 |
|
Selects CH1 from trigger source |
Shift + Ctrl + F1 |
Trigger Source CH2 |
|
Selects CH2 from trigger source |
Shift + Ctrl + F2 |
Slope |
|
Selects Up/Down from Trigger Up/Down |
Shift + Ctrl + F3 |
Auto/Normal |
|
Selects Normal/Auto from Trigger Normal/Auto |
Shift + Ctrl + F4 |
Advanced Trigger |
|
Selects Advanced trigger |
Shift + Ctrl + F5 |
Trigger High Frequency Reject On/Off |
|
Eliminate trigger high-frequency |
|
Acquire
Name |
Sub Menu |
Operation |
Hot-key |
Run/Stop |
|
Starts/Stops acquiring waveform |
Ctrl + R |
Single Shot |
|
Begins Single Shot operation |
Ctrl + H |
Auto Set |
|
Changes horizontal/vertical scale for waveform |
Ctrl + A |
ETS On/Off |
|
On/Off ETS |
|
Average |
|
Changes average count number |
|
Peak Detection |
|
Peak Detection On/Off |
|
Util
Name |
Sub Menu |
Operation |
Hot-key |
FFT |
|
Shows FFT form |
Ctrl + F |
Measurement |
Time |
- |
|
Voltage |
- |
|
Upper/Lower Level |
Upper/Lower |
|
XY plot On/Off |
|
On/Off XY plot |
Ctrl + Y |
Calibration |
|
Processes Offset calibration |
Shift + Ctrl + F6 |
ETS Calibration |
|
Processes ETS calibration |
|
Measure
Name |
Sub Menu |
Operation |
Hot-key |
Voltage |
Peak to Peak |
Measurement of Peak to Peak Voltage |
Ctrl + Alt + P |
Maximum |
Measurement of Maximum Voltage |
Ctrl + Alt + X |
Minimum |
Measurement of Minimum Voltage |
Ctrl + Alt + N |
Amplitude |
Measurement of Amplitude Voltage |
Ctrl + Alt + A |
Top |
Measurement of Top Voltage |
Ctrl + Alt + T |
Base |
Measurement of Base Voltage |
Ctrl + Alt + B |
Upper |
Measurement of Upper Voltage |
Ctrl + Alt + U |
Middle |
Measurement of Middle Voltage |
Ctrl + Alt + M |
Lower |
Measurement of Lower Voltage |
Ctrl + Alt + L |
Mean |
Measurement of Mean Voltage |
Ctrl + Alt + E |
Cycle Mean |
Measurement of Cycle Mean Voltage |
Ctrl + Alt + C |
RMS |
Measurement of RMS Voltage |
Ctrl + Alt + R |
Cycle RMS |
Measurement of Cycle RMS Voltage |
Ctrl + Alt + Y |
Positive Overshoot |
Measurement of Positive Overshoot Voltage |
Ctrl + Alt + S |
Negative Overshoot |
Measurement of Negative Overshoot Voltage |
Ctrl + Alt + G |
Time |
Period |
Measurement of Period |
Ctrl + Alt + I |
Frequency |
Measurement of Frequency |
Ctrl + Alt + F |
Rise Time |
Measurement of Rise Time |
Ctrl + Alt + V |
Fall Time |
Measurement of Fall Time |
Ctrl + Alt + Z |
Positive Duty Cycle |
Measurement of Positive Duty Cycle |
Ctrl + Alt + J |
Negative Duty Cycle |
Measurement of Negative Duty Cycle |
Ctrl + Alt + D |
Positive Pulse Width |
Measurement of Positive Pulse Width |
Ctrl + Alt + W |
Negative Pulse Width |
Measurement of Negative Pulse Width |
Ctrl + Alt + H |
Upper/Lower Level |
|
Set Upper/Lower ratio |
|
Help
Name |
Sub Menu |
Operation |
Hot-key |
Help |
|
Shows help file |
F1 |
About |
|
Displays about Dialog Box |
F9 |
参考
- Menu - SoftScope Help (/help.chm)